Model: Fluke 62 MAX Infrared Thermometers
Temperature is often the first indication of potential problems in electrical and mechanical applications. But you can easily measure by Fluke 62 MAX Infrared Thermometers if an electrical panel has a hot spot, a motor is overheating or an HVAC system is inefficient?
The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems.
Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX+ infrared thermometers are everything you’d expect from the experts in measurement tools. Small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX+ are so tough, they’re the only IR thermometers around you can handle without care. Order through Tools Bangladesh we can deliver anywhere in Bangladesh.
Specifications: Fluke 62 MAX Infrared Thermometers
| Specifications |
| Temperature range |
-30°C to 500°C (-22°F to 932°F) |
| Accuracy |
±1.5°C or ±1.5% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
| Response time (95%) |
< 500 ms (95% of reading) |
| Spectral response |
8 to 14 microns |
| Emissivity |
0.10 to 1.00 |
| Optical resolution |
10:1 (calculated at 90% energy) |
| Display resolution |
0.1°C (0.2°F) |
| Repeatability of readings |
±0.8% of reading or < ±1.0°C (2°F), whichever is greater |
| Power |
AA battery |
| Battery life |
10 hours with laser and backlight on |
| Physical Specifications |
| Weight |
255 g (8.99 oz) |
| Size |
175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
| Operating temperature |
0°C to 50°C (32°F to 122°F) |
| Storage temperature |
-20°C to 60°C (-4°F to 140°F), (without battery) |
| Operating humidity |
10% to 90% RH non-condensing at 30°C (86°F) |
| Operating altitude |
2000 meters above mean sea level |
| Storage altitude |
12,000 meters above mean sea level |
| IP rating |
IP 54 per IEC 60529 |
| Drop test |
3 meters |
| Vibration and shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC |
EN 61326-1:2006 EN 61326-2:2006 |
| Standards and agency approval |
Compliance |
EN/IEC 61010-1: 2001 |
| Laser safety |
FDA and EN 60825-1 Class II |