Model: Fluke 117 Digital Multimeter
Fluke 117 Digital Multimeter consists of included non-admittance voltage detection to appease income so the behavior ended quicker.
Designed by Engineers and supposed through Fluke, the Fluke 117 Digital Multimeter might be a compact True-RMS meter for exacting packages among business buildings, hospitals, and colleges.
With its included non-touch voltage detection, Auto Volts and LoZ take scuffle that facilitates saving you two-time readings because of ghost voltage. Fluke is a for your liking alternative for engineers. In fact, customers withinside the area of the arena have aforementioned their 117 multimeter is the companion funding inaccuracy.
The Fluke 117 virtual multimeter gives Min/Max/Average readings and court cases frequency and capacitance. Plus, its easy-to-use interface will save you generation and fine-surroundings you to maneuver from process to process quite a few unexpectedly. We provide Fluke 117 Digital Multimeter with a satisfactory charge in BD from Unique Tools BD.
Key features: Fluke 117 Digital Multimeter
- Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection
- Presents a large white LED backlight for working in poorly lit areas
- Features True RMS capabilities for accurate measurements on non-linear loads
- Features AutoVolt automatic AC/DC voltage selection
- Provides low input impedance to help prevent false readings due to ghost voltage
Specifications: Fluke 117 Digital Multimeter
|
Specifications
|
|
600 V
|
|
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
|
|
11 A, 1000 V FAST Fuse (Fluke PN 803293)
|
|
Digital: 6,000 counts, updates 4 per second
|
|
33 segments, updates 32 per second
|
|
-10°C to +50°C
|
|
-40°C to +60°C
|
|
9 volt Alkaline, NEDA 1604A / IEC 6LR61
|
|
400 hours typical, without backlight
|
|
Accuracy Specifications
|
|
Range/resolution
|
600.0 mV / 0.1 mV
|
|
Accuracy
|
±([% of reading] + [counts]): 0.5% + 2
|
|
Range/resolution
|
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
|
|
Accuracy
|
±([% of reading] + [counts]): 0.5% + 2
|
|
Range/resolution
|
600.0 V / 0.1 V
|
|
Accuracy
|
2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
|
|
Range/resolution
|
600.0 mV / 0.1 mV
|
|
Accuracy
|
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
|
|
Range/resolution
|
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
|
|
Accuracy
|
1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
|
|
Range/resolution
|
600 Ω / 1 Ω
|
|
Accuracy
|
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
|
|
Range/resolution
|
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
|
|
Accuracy
|
0.9% + 1
|
|
Range/resolution
|
40.00 MΩ / 0.01 MΩ
|
|
Accuracy
|
5% + 2
|
|
Range/resolution
|
2.00 V / 0.001 V
|
|
Accuracy
|
0.9% + 2
|
|
Range/resolution
|
1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
|
|
Accuracy
|
1.9% + 2
|
|
Range/resolution
|
> 1000 μF
|
|
Accuracy
|
5% + 20%
|
|
Range
|
1 nF to 500 μF
|
|
Accuracy
|
10% + 2 typical
|
|
Range/resolution
|
6.000 A / 0.001 A 10.00 A / 0.01 A
|
|
Accuracy
|
1.5% + 3 20 A continuous overload for 30 seconds max
|
|
Range/resolution
|
6.000 A / 0.001 A 10.00 A / 0.01 A
|
|
Accuracy
|
1.0% + 3 20 A continuous overload for 30 seconds max
|
|
Range/resolution
|
99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz
|
|
Accuracy
|
0.1% + 2
|
|
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of the range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. The frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
|
|
Mechanical and General Specifications
|
|
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
|
|
550 g
|
|
3 years
|